 US
EPA TO-17 is the New International Standard
for the
"Determination of VOCs in Ambient
Air using Active Sampling onto Sorbent
Tubes."
Validated for the widest range of VOCs, down
to below one nanogram per sample ( <0.1 ppbv
in air ).
Sampling is by Solid Sorbent
"Air Toxics" Tube, recognised as having
many advantages over canister and other sampling
methods.The VOCs are transferred directly from
the sampling tube to the GC-MS (Gas Chromatograph
Mass Spectrometer), eliminating interference
and loss of sensitivity.
This allows for targeting
of specific compounds plus identification of
other compounds all in one test.
EPA TO-17 is suitable for a
wide range of application including:
- Environmental / Ambient / Indoor
- Occupational / Industrial Hygiene
- Source / Emissions / Stack
- Soil Gas / Flux Emissions
The Chromatographic profile
below shows the Volatile Organic Compounds identified
in rural - residential ambient air.
The peaks include benzene,
toluene and other VOCs plus a range of volatile
essential oils such as limones and pinenes from
the nearby vegetation. Concentrations are in
the range of 0.1-1 ppb.
This method has been used to
measure benzene in the Arctic Circle down to
15 parts per trillion which equates to about
60 picograms being detected on the thermal desorption
sampling tube.
Sampling Procedures & Media
form an integral part of obtaining reliable
results. We work with our clients to ensure
the proposed sampling techniques will satisfy
their “DQOs”, (data quality objectives).
Each sampling tube is individually analysed
and “certified clean” prior to being
supplied for sampling. Gas samples can also
be collected in Tedlar Gas Bags and transferred
to sorbent tubes for analysis.
Analytical Technology includes
a high tech, state of the art, Automated Thermal
Desorber coupled with a High Resolution Capillary
Gas Chromatography – Mass Spectrometry.
This equipment offers superior sensitivity &
specificity, allowing for a wide range of compounds
to be analysed in the one test. |